We use cookies to store information that makes it easier for you to use our website - for example, which language you want to use. These cookies do not store any personally identifiable information. You can set your browser to block or alert you about these cookies, but some parts of the website will not then work.

By continuing to use the website, you are agreeing to our Cookies Policy
Key: Subject to VAT Reserve price met

GE Voluson E8 Ultrasound

Serial Number:
d00843

Manufacture Date:
06 / 2007

Associated Equipment:
GE RIC6-12-D Transducer
Serial number: 74041KR5
Manufactured: 04-2007

GE RAB4-8-D Transducer
Serial number: 78717KR6
Manufactured: 07-2008

Software:
6.2.4.1423

Condition Report:
The GE Voluson E8 Expert ultrasound system powers up and completes self-test, with software and user interface working as expected. Gain controls, trackball, keyboard, soft function keys and LCD screens are in good working condition. The backlight for the touch screen LCD is not working, although the touch screen is still functional. Patient registration and storage is fully functional. Electromagnetic lock and associated horizontal adjustment and motorised vertical adjustment; with regards to the control assembly adjustments. Screen height adjustment is stable at different elevations. The RIC6-12-D and RAB4-8-D transducers show no crystal element damage or loose connections in cabling that would otherwise distort the image. There is some slight membrane wear around the base of the RAB4-8-D transducer, but this does not affect the image quality. Each transducer was tested with a test phantom. The RIC6-12-D and RAB4-8-D transducers were found to have fair resolution, good grey scale and good image quality. All calliper measurements were accurate for each transducer. The unit was tested on PW, M, PD, C, TD, 2D, 3D and 4D modes; with all being fully functional. LCD has all function menus accessible, but the touch screen function menus are not visible due to the lack of backlight. Printer is in good physical and working condition. The wheel-casters are in good working condition. The Freeze and P1 keys have become worn slightly from repeated use, as well as missing the front panel, otherwise the system is in good physical condition, with side and back panels intact as expected.


Location:
Malmesbury, Wiltshire, UK

Viewing:
By appointment with the Auctioneer

Removal:
By Friday 21st June 2019

For every £100 you spend you will pay £20 Buyers Premium plus £4 VAT on that Premium [non-refundable] and on VAT registered lots £20 Hammer VAT [refundable upon proof of export].
All new and used medical, catering and general equipment lots are sold as seen. Any views expressed are for guidance only - please refer to our conditions of sale.

Printable Lot Details

Ends Fri 14 Jun 2019 | 12:16:33

Close Of Bidding EXTENDED

Lot Number: 1  

Sale Number: 50988

Medical | Timed Online Auction

Sale Currency: £ UK Pound Sterling