We use cookies to store information that makes it easier for you to use our website - for example, which language you want to use. These cookies do not store any personally identifiable information. You can set your browser to block or alert you about these cookies, but some parts of the website will not then work.

By continuing to use the website, you are agreeing to our Cookies Policy
Key: Subject to VAT Reserve price met

Philips iU22 Ultrasound

Serial Number:
B03XGW

Manufacture Date:
03 / 2011

Associated Equipment:
Philips L9-3 Transducer
Serial number: 03D2GM

Philips L17-5 Transducer
Serial number: 030F7G

Philips C5-1 Transducer
Serial number: B07YQ7

Philips C8-4v Transducer
Serial number: 02XY15

Accessories:
Foot Switch

Software:
6.0.0.845
Service Hardware: Rev G.1

Condition Report:
The Philips iU22 ultrasound system powers up and completes self-test, with software and user interface working as expected. Gain controls, soft function keys, trackball, keyboard, touch and LCD screens are in good working condition. Transducer soft key is a little stiff, but is otherwise functional. Patient registration and storage is fully functional. Screen height adjustment is stable at different elevations. Vertical console assembly adjustment is in good working order. The L9-3, L17-5, C5-1 and C8-4v transducers show no crystal element damage or loose connections in cabling that would otherwise distort the image. There is some slight membrane wear at the edges of the L9-3 and L17-5 transducers, but these do not affect the image quality. Each transducer was tested with a test phantom. The L9-3 and L17-5 transducers were found to have good resolution, good grey scale and good mage quality. The C5-1 transducer was found to have fair resolution, good grey scale and good mage quality. The C8-4v transducer was found to have poor resolution, fair grey scale and fair image quality. All calliper measurements were found to be accurate for each transducer. The unit was tested on M, CPA, PW, Colour, 2D and 3D modes; with all being fully functional. LCD and touch screens have all function menus accessible. Printer is not included with this unit. The footswitch is in good physical and working condition. The wheel-lock mechanism is in good working condition. The system is in fair physical condition, with some minor cracks on the M-mode function selector.
Location:
Malmesbury, Wiltshire, UK

Viewing:
By appointment with the Auctioneer

Removal:
By Friday 21st June 2019

For every £100 you spend you will pay £20 Buyers Premium plus £4 VAT on that Premium [non-refundable] and on VAT registered lots £20 Hammer VAT [refundable upon proof of export].
All new and used medical, catering and general equipment lots are sold as seen. Any views expressed are for guidance only - please refer to our conditions of sale.

Printable Lot Details

Ends Fri 14 Jun 2019 | 12:23:29

Close Of Bidding EXTENDED

Lot Number: 5  

Sale Number: 50988

Medical, Imaging | Timed Online Auction

Sale Currency: £ UK Pound Sterling